Pumps, Fans and Affinity Laws: A Practical Guide
The affinity laws: Q ∝ N, H ∝ N², P ∝ N³. A small speed increase can significantly raise power.
Example: +10% speed → ~+10% flow, ~+21% head, ~+33% power
Design implications: avoid oversizing, maintain design ΔT, and use VFD turndown wisely.